摘要: 介绍了用直流电压源和锰铜压力计测量压力的一种方法。该方法的测量电路非常简单,便于匹配,与以往传统的脉冲电源供电的测量方法相比,不仅可省去触发系统,而且由于流过压力计的电流很小(约20 mA),所产生的派生磁场对样品和飞片的磁化作用减少了两个数量级以上。同时此法也是一种低成本的压力测量方法。Abstract: A method for manganin piezoresistance measurement that uses a D. C. power supply is described. This technique is very simple and easy to match. Compared with the conventional technique which uses pulse power supply, it not only omits the trigger system, but also can reduce the electromagnetic disturbance which is caused by the magnetic field derived from the current traversing in the gauge, because the current flowing over the gauge is very weak (about 20 mA). Furthermore, the technique is also a low cost method for dynamic pressure measurement.
-
Key words:
- manganin stress gauge /
- stress measurement /
- D. C. power supply /
- pulse power supply
-
Oved Y, Luttwak G, Rosenberg Z. J Comps mater, 1978, 12: 84. 胡泽根, 吴光华, 曹述生. 爆炸与冲击, 1988, 8(3): 249. 陈雪芳, 马法成, 张若棋. 爆炸与冲击, 1988, 8(3): 243. 王翔, 傅秋卫. 髙压物理学报, 1996, 10(2): 157. Vantine H C, Chan J, et al. Rev Sci Instrum, 1980, 51(1): 116. 王诚洪, 马法成. 爆炸与冲击, 1987, 7(1): 41. 金孝刚. 低压下镍的力学特性及相结构研究. 私人通讯, 1995. Rosenberg Z, Yaziv D, Partom Y. J Appl Phys, 1980, 51(7): 3702. Rosenberg Z, Ginzburg A. On the Source for Failure of Commercial Manganin Gauges at High Shcok Pressures. In: Schmidt S C, Tao W C, ed. Shock Waves in Condensed Matter-1995. New York: American Institute of Physics, 1996: 1049-1052. Sheffield S A, Bloomquist D D. Low Pressure Hugoniot in Polymeric Materials. In: Nellis W J, Seaman L, Graham R A, ed. Shock Waves in Condensed Matter-1981. New York: American Institute of Physics, 1982: 57-61. -